Atellica CI 1900 integrated system for biochemical and immunoassays

Manufacturer:Siemens Healthineers
Country:Germany

Specialist consultation

+38 (044) 223 14 06

Details

Characteristics

Validated Sample TypesSerum, plasma, amniotic fluid, urine, whole blood (assay-specific), CSF, and other
Auto-reflex TestingConfigurable; additional tests based on results of first test or test mix
Reaction Cuvettes (clinical chemistry)CH reaction ring segments (clinical chemistry = 130 reusable cuvettes, 10 segments, 13 cuvettes)
Reaction TemperatureCH: 37°C ±0.3°C, IM: 37°C ±0.4°C
Assay TimeChemistry and immunoassay: 1–54 minutes, assay-dependent
Sample Integrity ControlLiquid-level sensing, clot/clog detection, bubble detection, short-sample detection; hemolysis, icterus, and lipemia
Assay Technology CHIntegrated Multisensor Technology (IMT, electrolytes), photometric, and turbidimetric
Quality Control ReviewAdvanced QC package with graphical display of QC in real time, including patient moving averages, Levey-Jennings plots, Westgard rules; up to 125,000 control results can be stored; autovalidation, archivable to removable media.
Onboard capacity113 assays (70 reagent clinical chemistry positions, 3 IMTs, 20 primary and 20 ancillary immunoassay positions)
Auto-repeatAutomatic repeat testing from the original and diluted samples
Reaction CuvettesCH dilution cuvettes (64 reusable cuvettes: four segments with 16 cuvettes each)
Reaction Cuvettes (IM)IM incubation ring holds 56 cuvettes.
Chemistry Reaction DetectionReaction area: photometer, LED light source with 11 fixed wavelengths (340, 410, 451, 478, 505, 545, 571, 596, 658, 694, 805 nm). Linearity: 0–3.0 AU. Resolution: 0.0001 AU.
Sample Volume per Test2–100 μL of sample (varies by assay)
Immunoassay Reaction FormatsSandwich, competitive, and antibody-capture/antigen-bridge formats
Assay Technology IMChemiluminescence testing methodology using advanced acridinium ester technology
Reagent Integrity ControlReagent pack barcode identification: automatic pack/well tracking, notification of inventory, calibration and control validity, onboard stability, low and expired reagents, detection of reagent bubbles

Service and Warranty

We provide premium service and maintenance for every device and consumable:

 

Comprehensive maintenance of medical equipment

Installations, commissioning

Warranty and post-warranty service

Instruction, training and consultations for your team

 

More details on the SERVICE page

 