• Automatic biochemical analyzer Dirui CS-680
    • Automatic biochemical analyzer Dirui CS-680 - Picture 2
    • Automatic biochemical analyzer Dirui CS-680 - Picture 3
    • Automatic biochemical analyzer Dirui CS-680
    • Automatic biochemical analyzer Dirui CS-680 - Picture 2
    • Automatic biochemical analyzer Dirui CS-680 - Picture 3

    Automatic biochemical analyzer Dirui CS-680

    Manufacturer:Dirui Industrial
    Country:People's Republic of China

    Specialist consultation

    +38 (044) 223 14 06

    Details

    Biochemical Automatic Analyzer Dirui CS-1200

    The Dirui CS-1200 is a high-performance automatic biochemical analyzer known for its enhanced reliability and high throughput - 800 test per hour, capable of meeting the needs of modern clinics and diagnostic laboratories. Its key advantage is the combination of high-speed analysis and accurate results, making it an indispensable tool for performing routine and specialized biochemical research. The analyzer is equipped with a halogen lamp with an extended lifespan, reducing the need for technical maintenance.

     

    ADVANTAGES:

    Throughput:

    • The CS-1200 typically achieves up to 800 tests per hour (without the ISE module).

    • With the ion-selective electrode (ISE) module, the throughput is 400 tests per hour.

    • Random access testing capability.

    Sample and Reagent Handling:

    • Holographic concave grating with flat-field, rear spectrophotometry.

    • Sample analysis: up to 132 samples can be processed simultaneously with continuous loading capability.

    • Cluster condensation light technology (point light source) allows for micro-volume analysis, reducing reagent consumption.

    • The durable light source uses a circulating water cooling method, designed to provide a stable signal with enhanced interference protection.

    • External light protection for accurate results.

    Analytical Accuracy:

    • Photometric technology with wavelengths ranging from 340 to 800 nm allows for a wide range of analyses.

    • Ensures reliable results with low sample and reagent consumption. The sample volume required for research is only 1.5-35 μl, with 0.1 μl increments.

    Operational Efficiency:

    • Automatic calibration and quality control (QC) procedures reduce manual intervention. Automatic trend description of calibrations. Notification in case of a sample that failed calibration, recording the reasons for calibration issues.

    • 9 types of calibration curves for different types of analysis.

    • Cross-contamination prevention program to avoid interference from different reagents, samples, and reaction cuvettes.

    • Supports STAT testing (urgent sample testing).

    • Tracks residual reagent volume.

    • Automatic calculation of analysis completion time, real-time display of the analysis process.

    User-Friendly Interface:

    • Intuitive, user-friendly interface with a touch screen and comprehensive software for managing samples, results, and QC.

    Wide Application Capabilities:

    • Suitable for various biochemical tests, including liver and kidney functions, electrolytes, glucose, lipids, and enzymes.

    High Reliability and Ease of Maintenance:

    • Automatic cuvette washing, with 12-step warm water washing ensuring thorough cleaning.

    • Inner probe wall washing. Vacuum drainage liquid, detergent, and high-pressure warm water washing minimize residual contamination to only 0.1%.

    • Built-in maintenance warning function and troubleshooting guide.

    Connectivity:

    • Supports integration with LIS (Laboratory Information System) and HIS (Hospital Information System) for seamless data management.

    Characteristics

    Sample throughputUp to 800 samples per hour and up to 400 samples with ISE module
    Sample typesSerum, plasma, urine, cerebrospinal fluid
    Reaction volumeMinimum reaction volume 120 µl
    WavelengthsFrom 340 to 800 nm
    Sample volume1.5 µl-35 µl
    Built-in hemolysis functionYes
    Ability to download STAT positionsYes
    Cooling system for reagentsYes
    Connection to LIS/HISYes
    Temperature ControlThe temperature of reaction disk incubation bath is 37°C±0.1°C
    Sample positions132 sample positions
    Calibration1 point linear, 2 point linear, multi-point linear, nonlinear calibration
    Principles of testingColorimetry, turbidimetry, ISE
    Analysis methodsEndpoint, kinetics, fixed time, and others. Supports single and dual wavelengths, single and dual reagent methods
    Clot detection and collision protectionYes
    Real-time display of the analysis processYes
    Sample containersTest tubes and standard sample cups
    Reaction cuvettes160 reusable reaction cuvettes
    Sample position140 sample position

    Service and Warranty

    We provide premium service and maintenance for every device and consumable:

     

    • Comprehensive maintenance of medical equipment
    • Installations, commissioning
    • Warranty and post-warranty service
    • Instruction, training and consultations for your team

     

    More details on the SERVICE page

    Contact phone+38 (067) 133 05 52
    E-mail:service@empirica.healthcare