- Home/
- Products/
- Molecular diagnostics/
- PCR/
- PCR reagent kits/
- GeneProof® Herpes Simplex Virus (HSV-1/2) PCR Kit - (IVDR)
- TOP
- IVDR
GeneProof® Herpes Simplex Virus (HSV-1/2) PCR Kit - (IVDR)
Manufacturer: | GeneProof |
---|---|
Country: | Czech Republic |
Specialist consultation
+38 (067) 880 44 83Details
MORE INFORMATION FROM ONE REACTION
PCR kit detects and distinguishes Herpes Simplex Virus 1 and Herpes Simplex Virus 2 in a single reaction tube
EXCELLENT QUALITY
The highest possible diagnostic sensitivity (100.00%) and diagnostic specificity (96.08%)
SIMPLE LABORATORY WORKFLOW
Easily combinable with other GeneProof PCR kits in one workflow
EASY-TO-USE CONCEPT
Single tube Ready-to-Use Master Mix contains all components for PCR amplification
No additional PCR reagents pipetting necessary
CONTAMINATION PREVENTION
Ready-to-Use Master Mix contains Uracil-DNA glycosylase (UNG) and dUTPs eliminating possible carryover contamination
COMPATIBLE WITH A WIDE RANGE OF REAL-TIME PCR DEVICES
CE IVD CERTIFIED DIAGNOSTIC TEST
HSV/GP/025 - 25 tests
HSV/GP/100 - 100 tests
Characteristics
INDICATION | in vitro diagnostic medical device |
---|---|
TECHNOLOGY | Real-time PCR |
TARGET SEQUENCE | Gene encoding B glycoprotein (gB) |
DIAGNOSTIC SPECIFICITY | 96.08 % (CI95%: 89.69 % – 98.74 %) |
POSITIVE PREDICTIVE VALUE | 98.65 % (CI95%: 96.34 % – 99.57 %) |
DYNAMIC RANGE | 10*10 – LoD cp/ml (LoD varying according to the extraction, material and channel used) |
CONVERSION FACTOR | Not applicable |
EXTRACTION/INHIBITION CONTROL | PCR inhibition and DNA extraction efficiency control by Internal Control (IC) |
STORAGE | (-20 ± 5) °C |
APPLIED INSTRUMENTS | ▪ croBEE Real-Time PCR System ▪ AMPLilab Real-Time PCR System ▪ Applied Biosystems 7500 Real-Time PCR System ▪ AriaMx Real-Time PCR System ▪ BioQuant-96 Real-Time PCR System ▪ CFX96/ Dx Real-Time PCR Detection System ▪ CFX Opus 96 Real-Time PCR System ▪ Gentier 96E/96R Real-Time PCR System ▪ LightCycler® 480 ▪ LineGene 9600 / 9600 Plus ▪ Mic qPCR Cycler ▪ uantStudio™ 5 Real-Time PCR System ▪ Rotor-Gene 3000 / Q ▪ SLAN® Real-Time PCR System |
EXTERNAL QUALITY ASSESSMENT | Regularly tested in QCMD and Instand e.V. External Quality Assessment Panels – results at www.geneproof.com |
REGULATORY STATUS | CE IVD / Regulation (EU) 2017/746 |
---|---|
TYPE OF ANALYSIS | Qualitative and quantitative |
ANALYTICAL SPECIFICITY | Herpes simplex virus type 1 (HSV-1), 100 %, Herpes simplex virus type 2 (HSV-2), 100 % |
DIAGNOSTIC SENSITIVITY | 100 % (CI95%: 98.38 % – 100 %) |
NEGATIVE PREDICTIVE VALUE | 100 % (CI95%: 95.30 % – 100 %) |
REPORTING UNITS | cp/ml |
METROLOGICAL TRACEABILITY | AcroMetrix HSV-1 Plasma Panel (AcroMetrix HSV-1) | AcroMetrix HSV-2 Plasma Panel (AcroMetrix HSV-2) |
VALIDATED SPECIMEN | DNA extracted from CSF, plasma, serum, urine, swab (genital, vesicular), whole blood (EDTA) |
VALIDATED EXTRACTION METHOD | ▪ croBEE 201A Nucleic Acid Extraction Kit ▪ myCROBE/croBEE 2.0 Universal Extraction Kit ▪ GeneProof PathogenFree DNA Isolation Kit |
DETECTION CHANNELS | FAM (HSV-1), HEX/JOE/VIC (IC), Cy5 (HSV-2) |
Service and Warranty
Contact phone | +38 (067) 133 05 52 |
---|---|
E-mail: | service@empirica.healthcare |