    Nanoparticle Measurement System Pulsoid

    Manufacturer:Izon Science
    Country:New Zealand

    Specialist consultation

    +38 (067) 880 44 83

    Details

    Pulsoid is an innovative high-precision nanoparticle measurement system based on Nanopore Pulse Sensing (NPS) technology. The instrument provides direct, single-particle analysis of size, concentration, and zeta potential with TEM-level accuracy and high throughput.

     

    High-Resolution Single-Particle Analysis

     

    Pulsoid performs single-particle analysis, enabling detection of heterogeneity and particle subpopulations that are not identified by ensemble methods (e.g., DLS).

     

    TEM-Level Size Accuracy

     

    Size measurement accuracy up to 100% ±2%, with 99.7% agreement compared to TEM (for NIST-traceable standards).

     

    Direct Particle Counting

     

    Concentration is determined by direct counting of each individual particle, ensuring a linear response across a wide concentration range.

     

    Simultaneous Zeta Potential Measurement

     

    Pulsoid simultaneously measures particle size and zeta potential on a particle-by-particle basis, enabling detailed analysis of surface charge and formulation stability.

     

    Solid-State Silicon Nanopore Chip

     

    The system is built around a precision-manufactured silicon nanopore chip with fixed pore geometry, providing:

    • Signal stability

    • High reproducibility

    • Minimal calibration requirements

    • Easy cleaning

     

    Optimised for LNP

     

    The system is designed for the analysis of:

    • Lipid nanoparticles (LNP)

    • Exosomes

    • Virus-like particles

    • Polymeric nanoparticles

     

    Laboratory Benefits

     

    1. Sample analysis in 2–5 minutes
    2. High throughput
    3. Reduced user error risk
    4. Simple setup and short training time

    Characteristics

    Measurement MethodNanopore Pulse Sensing (NPS)
    Size Measurement Range40–140 nm (expansion expected)
    Minimum Detectable Size40 nm
    Concentration MethodDirect particle counting
    Analysis Time per Sample2–5 minutes
    Analysis TypeSingle-particle
    Measured ParametersSize, concentration, zeta potential
    Size Accuracy100% ± 2%
    Concentration Range1 × 10⁹ – 1 × 10¹² particles/mL
    Sample Volume70 µL
    Nanopore TypeSolid-state silicon

    Service and Warranty

    We provide premium service and maintenance for every device and consumable:

     

     Comprehensive maintenance of medical equipment

     Installations, commissioning

     Warranty and post-warranty service

     Instruction, training and consultations for your team

     

    More details on the SERVICE page

    Contact phone+38 (067) 133 05 52
    E-mail:service@empirica.healthcare